Product images:
Description
-
Output range from 3,000 to 4,500 kWel - MWM's largest series
-
Runs on all gas types: natural gas, landfill gas, sewage gas, mine gas, coke oven gas, biogas***
-
Mainly used in large IPP projects with up to 100,000 kWel
-
High Efficiency and Low Lubricant Consumption
-
High fuel utilization and low operation costs thanks to optimized chamber spark plug
-
Increased efficiency through new closed crankcase ventilation that enables utilization of the blow-by gas
-
High availability through long maintenance intervals: first maintenance after 4,000 h, major overhaul after 80,000 h
-
With its lubricant consumption of only 0.2 g/kWh up to 30 percent lower lubricant consumption compared to competitor products thanks to optimized tappet sealing, coke stripping rings and ring packages
Soot-Free Combustion Increases Plant Profitability
-
Open combustion chamber with chamber spark plug for soot-free combustion
-
Extended maintenance intervals for the exhaust gas heat exchanger
-
No pre-combustion chamber with time-consuming maintenance and risk of failure
-
No additional gas supply with increased gas pressure required for pre-combustion chamber
Few Interruptions Due to Long Maintenance Intervals
-
No more than two interruptions a year due to scheduled maintenance
-
Longest interval until major overhaul compared to competitors
-
Use of Xchange components enables time savings of up to 75 percent during the major overhaul, resulting in reduced costshttps://issuu.com/mwm_energy/docs/mwm_lb_tcg_2032_en
Natural gas applications, NOx ≤ 500 mg/Nm3 *
TCG 2032 V12
Engine type 50 Hz 60 Hz**
Electrical output kW 3333 3000
Mean effective pressure bar 20.0 20.1
Thermal output ± 8% kW 3238 2877
Electrical efficiency % 43.9 43.9
Thermal efficiency % 42.6 42.1
Total efficiency % 86.5 86.0
Power to heat ratio*** 1.03 1.04
TCG 2032 V16 TCG 2032B V16
Engine type 50 Hz 60 Hz** 50 Hz 60 Hz**
Electrical output kW 4300 4000 4500 4000
Mean effective pressure bar 19.4 20.2 20.3 20.4
Thermal output ± 8% kW 4164 3866 4259 3891
Electrical efficiency % 44.1 43.8 44.6 44.3
Thermal efficiency % 42.7 42.4 43.2 42.6
Total efficiency % 86.8 86.2 87.8 86.9
Power to heat ratio*** 1.03 1.03 1.03 1.04
* 5% O2 and dry exhaust gases
** On request
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
Biogas, landfill gas, and sewage gas applications, NOx ≤ 500 mg/Nm3 *
TCG 2032 V16
Engine type 50 Hz 60 Hz**
Electrical output kW 3770 3510
Mean effective pressure bar 17.0 17.0
Thermal output ± 8% kW 3496 3125
Electrical efficiency % 43.0 43.3
Thermal efficiency % 39.8 38.5
Total efficiency % 82.8 81.8
Power to heat ratio*** 1.08 1.12
* 5% O2 and dry exhaust gases
** On request
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.